P1 telemetry

What the EVSE-SC-02 reads from the DSMR/ESMR 5 smart meter P1 port, with OBIS codes, and what it needs from the port electrically. Also the fields the Matter P1 power meter exposes.

View as MarkdownUpdated 2026-09-22

Port requirements

Meter DSMR 5.0 or ESMR 5.0 (Netherlands), Fluvius (Belgium). DSMR 4 and Austrian encrypted P1 are not supported.
Connector RJ12, 6P6C
Signal 115200 baud, 8N1, inverted TTL, data-request pin held high
Interval 1 telegram per second
Power Meter must supply ≥ 250 mA on pin 1. Otherwise power the SC-02 via micro-USB or use a powered splitter.

Fields used for load balancing

OBIS Field Use
1-0:21.7.0 Instantaneous active power L1 delivered (kW) Site load per phase
1-0:41.7.0 Instantaneous active power L2 delivered (kW) Site load per phase
1-0:61.7.0 Instantaneous active power L3 delivered (kW) Site load per phase
1-0:22.7.0 Instantaneous active power L1 returned (kW) Solar export per phase
1-0:42.7.0 Instantaneous active power L2 returned (kW) Solar export per phase
1-0:62.7.0 Instantaneous active power L3 returned (kW) Solar export per phase
1-0:31.7.0 Instantaneous current L1 (A) Site current, integer amps on most meters
1-0:51.7.0 Instantaneous current L2 (A) Site current
1-0:71.7.0 Instantaneous current L3 (A) Site current
1-0:32.7.0 Instantaneous voltage L1 (V) Per-phase voltage
1-0:52.7.0 Instantaneous voltage L2 (V) Per-phase voltage
1-0:72.7.0 Instantaneous voltage L3 (V) Per-phase voltage

Because the current fields are integer amps on most meters, the site controller derives current per phase from power and voltage (P / V) and uses the meter current only as a cross-check.

Fields used for reporting

OBIS Field
1-0:1.8.1, 1-0:1.8.2 Energy delivered, tariff 1 and 2 (kWh)
1-0:2.8.1, 1-0:2.8.2 Energy returned, tariff 1 and 2 (kWh)
0-0:96.14.0 Active tariff
0-0:1.0.0 Timestamp
0-0:96.1.1 Meter serial

What the site controller publishes

Site totals per phase go out in pwh_site_status every 5 minutes and on change; see MQTT topics. site_current_1..3 are decimal amps.

Matter P1 power meter

The same P1 parsing runs on the Matter power meter module (ESP32-C6, Thread). It exposes three Electrical Sensor endpoints with the Electrical Power Measurement cluster (0x0090): Voltage (mV), ActiveCurrent (mA) and ActivePower (mW) per phase, signed so that export is negative, updated every second.